Show simple item record

contributor authorIraklis A. Nikoletos
date accessioned2022-01-30T20:41:47Z
date available2022-01-30T20:41:47Z
date issued10/1/2020 12:00:00 AM
identifier other%28ASCE%29HZ.2153-5515.0000544.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4266957
description abstractIn this paper, we have studied ways to minimize the cost of stepwise or intermittent pumping from a system of wells under transient groundwater flow conditions. We take into account infinite confined aquifers and semi-infinite aquifers where the method of images applies Moreover, we examine optimal separation of wells in groups, in the case of alternate pumping. We have proved analytically via the method of Lagrange multipliers that, at any time, the pumping cost is minimized when the hydraulic head level drawdowns at the locations of the pumping wells are equal to each other.
publisherASCE
titleAnalytical Solutions of Intermittent Transient Groundwater Pumping Cost
typeJournal Paper
journal volume24
journal issue4
journal titleJournal of Hazardous, Toxic, and Radioactive Waste
identifier doi10.1061/(ASCE)HZ.2153-5515.0000544
page7
treeJournal of Hazardous, Toxic, and Radioactive Waste:;2020:;Volume ( 024 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record