Show simple item record

contributor authorDavid A. Chin
date accessioned2022-01-30T19:28:01Z
date available2022-01-30T19:28:01Z
date issued2020
identifier other%28ASCE%29EE.1943-7870.0001677.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4265353
description abstractVarious protocols are used in the hydraulic design of sanitary sewers, with key differences related to the assurance of self-cleansing, and the selection of Manning’s n. Analyses reported in this paper show that (1) self-cleansing of sewer pipes should not generally be assessed based on a specified full-flow velocity, (2) the typical Manning’s n values for specified pipe diameters recommended by ASCE are not generally appropriate, and (3) an exact analytic relationship between the minimum self-cleansing slope and the minimum flow rate can replace the empirical relations recommended by ASCE.
publisherASCE
titleIssues in Hydraulic Design of Sanitary Sewers
typeJournal Paper
journal volume146
journal issue4
journal titleJournal of Environmental Engineering
identifier doi10.1061/(ASCE)EE.1943-7870.0001677
page04020016
treeJournal of Environmental Engineering:;2020:;Volume ( 146 ):;issue: 004
contenttypeFulltext