Show simple item record

contributor authorLiu, Jian
contributor authorHussain, Safeer
contributor authorWang, Wei
contributor authorWang, Lei
contributor authorXie, Gongnan
contributor authorSundén, Bengt
date accessioned2019-09-18T09:04:13Z
date available2019-09-18T09:04:13Z
date copyright2/27/2019 12:00:00 AM
date issued2019
identifier issn0022-1481
identifier otherht_141_04_041702.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258494
description abstractIn internal cooling passages in a turbine blade, rib structures are widely applied to augment convective heat transfer by the coolant passing through over the ribbed surfaces. This study concentrates on perforated 90 deg ribs with inclined holes in a cooling duct with rectangular cross section, aiming at improving the perforated holes with additional secondary flows caused by inclined hole arrangements. Two sets of perforated ribs are used in the experiments with the inclined angle of the holes changing from 0 deg to 45 deg and the cross section are, respectively, circular and square. Steady-state liquid crystal thermography (LCT) is applied to measure the ribbed surface temperature and obtain corresponding convective heat transfer coefficients (HTCs). Two turbulence models, i.e., the k–ω shear stress transportation (SST) model and the detached eddy simulation (DES) model, are used in the numerical studies to simulate the flow fields. All the inclined cases have slightly larger overall averaged Nusselt number (Nu) than with straight cases. The enhancement ratio is approximately 1.85–4.94%. The averaged Nu in the half portion against the inclined direction is enlarged for the inclined hole cases. The inclined hole cases usually have smaller averaged Nu in the half portion along the inclined direction. For the straight hole case and small inclined angle case, the penetrated flows mix with the mainstream flows at the perforated regions. When the inclined angle is larger, the penetrated flows are pushed to the inclined direction and mixing with the approaching flows occurs just at the side of the inclined direction.
publisherAmerican Society of Mechanical Engineers (ASME)
titleHeat Transfer Enhancement and Turbulent Flow in a Rectangular Channel Using Perforated Ribs With Inclined Holes
typeJournal Paper
journal volume141
journal issue4
journal titleJournal of Heat Transfer
identifier doi10.1115/1.4042841
journal fristpage41702
journal lastpage041702-15
treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)