YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Hydrologic Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Hydrologic Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Applications of Linked and Nonlinked Complex Models for TMDL Development: Approaches and Challenges

    Source: Journal of Hydrologic Engineering:;2019:;Volume ( 024 ):;issue: 001
    Author:
    Yusuf Mohamoud; Harry Zhang
    DOI: 10.1061/(ASCE)HE.1943-5584.0001721
    Publisher: American Society of Civil Engineers
    Abstract: The choice of a model for total maximum daily load (TMDL) development for impaired water bodies depends mainly on the modeling objectives and system complexity. System complexity and modeling objectives, in turn, determine the required model complexity. Nonlinked or stand-alone complex models or linked models are generally selected for complex systems that consist of large watersheds with urban and rural areas and with a network of flow-controlled water impoundments (e.g., lakes and reservoirs) and estuaries. As an example, we present herein three case studies to demonstrate the role that complex nonlinked and linked models play in the development of complex TMDL studies. Case 1 is the Cannon River watershed, which uses a nonlinked complex model known as Hydrological Simulation Program—FORTRAN (HSPF), which is the core watershed model of the Better Assessment Science Integrating Point and Non-Point Sources (BASINS). Case 2 is the Chesapeake Bay watershed, which uses linked models: air-shed, watershed loading, and estuary models. Note that Case 2 uses the Chesapeake Bay Phase 5.3 Community Watershed Model, which is a version of the HSPF model. Case 3 is the Sougahatchee Creek watershed, which uses three linked models: Loading Simulation Program in C++ (LSPC), Water Quality Simulation Program (WASP), and Environmental Fluid Dynamics Code (EFDC). The results obtained from the case study reports show an absence of quantitative model performance metrics for Case 3 and limited performance results for Cases 1 and 2. For Case 2—a linked model case—model performance is only available for the loading model but not for the other linked models. The use of complex nonlinked models or linked models is not a guarantee of a good modeling practice by itself unless the models are supported by performance metrics, such as Nash–Sutcliffe efficiency (NSE) values that are greater than or equal to 0.65. Only Case 2 reported simulated water quality constituent NSE values for the watershed loading model, and reported values were less than zero. The low predictive performances gleaned from the case study reports can be attributed to inadequate system representation, model structure uncertainty, and poor data quality. Unless complex stand-alone and linked models are supported by accurate system representation and good quality input data, their application for TMDL development may not be scientifically defensible.
    • Download: (661.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Applications of Linked and Nonlinked Complex Models for TMDL Development: Approaches and Challenges

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4255042
    Collections
    • Journal of Hydrologic Engineering

    Show full item record

    contributor authorYusuf Mohamoud; Harry Zhang
    date accessioned2019-03-10T12:11:09Z
    date available2019-03-10T12:11:09Z
    date issued2019
    identifier other%28ASCE%29HE.1943-5584.0001721.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4255042
    description abstractThe choice of a model for total maximum daily load (TMDL) development for impaired water bodies depends mainly on the modeling objectives and system complexity. System complexity and modeling objectives, in turn, determine the required model complexity. Nonlinked or stand-alone complex models or linked models are generally selected for complex systems that consist of large watersheds with urban and rural areas and with a network of flow-controlled water impoundments (e.g., lakes and reservoirs) and estuaries. As an example, we present herein three case studies to demonstrate the role that complex nonlinked and linked models play in the development of complex TMDL studies. Case 1 is the Cannon River watershed, which uses a nonlinked complex model known as Hydrological Simulation Program—FORTRAN (HSPF), which is the core watershed model of the Better Assessment Science Integrating Point and Non-Point Sources (BASINS). Case 2 is the Chesapeake Bay watershed, which uses linked models: air-shed, watershed loading, and estuary models. Note that Case 2 uses the Chesapeake Bay Phase 5.3 Community Watershed Model, which is a version of the HSPF model. Case 3 is the Sougahatchee Creek watershed, which uses three linked models: Loading Simulation Program in C++ (LSPC), Water Quality Simulation Program (WASP), and Environmental Fluid Dynamics Code (EFDC). The results obtained from the case study reports show an absence of quantitative model performance metrics for Case 3 and limited performance results for Cases 1 and 2. For Case 2—a linked model case—model performance is only available for the loading model but not for the other linked models. The use of complex nonlinked models or linked models is not a guarantee of a good modeling practice by itself unless the models are supported by performance metrics, such as Nash–Sutcliffe efficiency (NSE) values that are greater than or equal to 0.65. Only Case 2 reported simulated water quality constituent NSE values for the watershed loading model, and reported values were less than zero. The low predictive performances gleaned from the case study reports can be attributed to inadequate system representation, model structure uncertainty, and poor data quality. Unless complex stand-alone and linked models are supported by accurate system representation and good quality input data, their application for TMDL development may not be scientifically defensible.
    publisherAmerican Society of Civil Engineers
    titleApplications of Linked and Nonlinked Complex Models for TMDL Development: Approaches and Challenges
    typeJournal Paper
    journal volume24
    journal issue1
    journal titleJournal of Hydrologic Engineering
    identifier doi10.1061/(ASCE)HE.1943-5584.0001721
    page04018055
    treeJournal of Hydrologic Engineering:;2019:;Volume ( 024 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian