| contributor author | Fernando Ferreira; Luís Simões | |
| date accessioned | 2019-03-10T12:00:33Z | |
| date available | 2019-03-10T12:00:33Z | |
| date issued | 2019 | |
| identifier other | %28ASCE%29CF.1943-5509.0001285.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4254631 | |
| description abstract | Pedestrian-induced actions cause high vibration amplitudes in flexible and lightweight structures such as cable-stayed bridges. The high vibrational response is considered a serious serviceability problem that must be avoided either at the design stage or when retrofitting the structure. The use of control devices, particularly tuned mass dampers (TMDs) and viscous dampers (VDs), can be justified to reduce the structural dynamic response. This paper concerns the optimum design of a cable-stayed steel footbridge and its control devices to withstand a running event while guaranteeing all the serviceability criteria. Four different techniques (no control, VD, and VD with passive or semiactive TMDs) are presented to illustrate the effect of these control strategies in the optimum design geometry, dynamic responses, and cost. | |
| publisher | American Society of Civil Engineers | |
| title | Optimum Design of a Controlled Cable-Stayed Footbridge Subject to a Running Event Using Semiactive and Passive Mass Dampers | |
| type | Journal Paper | |
| journal volume | 33 | |
| journal issue | 3 | |
| journal title | Journal of Performance of Constructed Facilities | |
| identifier doi | 10.1061/(ASCE)CF.1943-5509.0001285 | |
| page | 04019025 | |
| tree | Journal of Performance of Constructed Facilities:;2019:;Volume ( 033 ):;issue: 003 | |
| contenttype | Fulltext | |