Show simple item record

contributor authorFulker, David
contributor authorEne-Iordache, Bogdan
contributor authorBarber, Tracie
date accessioned2019-02-28T11:10:36Z
date available2019-02-28T11:10:36Z
date copyright1/19/2018 12:00:00 AM
date issued2018
identifier issn0148-0731
identifier otherbio_140_03_031011.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253487
description abstractArteriovenous fistulae (AVF) are the preferred choice of vascular access in hemodialysis patients; however, complications such as stenosis can lead to access failure or recirculation, which reduces dialysis efficiency. This study utilized computational fluid dynamics on a patient-specific radiocephalic fistula under hemodialysis treatment to determine the dynamics of access recirculation and identify the presence of disturbed flow. Metrics of transverse wall shear stress (transWSS) and oscillatory shear index (OSI) were used to characterize the disturbed flow acting on the blood vessel wall, while a power spectral density (PSD) analysis was used to calculate the any turbulence within the access. Results showed that turbulence is generated at the anastomosis and continues through the swing segment. The arterial needle dampens the flow as blood is extracted to the dialyzer, while the venous needle reintroduces turbulence due to the presence of jet flows. Adverse shear stresses are present throughout the vascular access and coincide with these complex flow fields. The position of the needles had no effect in minimizing these forces. However, improved blood extraction may occur when the arterial needle is placed further from the anastomosis, minimizing the effects of residual turbulent structures generated at the anastomosis. Furthermore, the arterial and venous needle may be placed in close proximity to each other without increasing the risk of access recirculation, in a healthy mature fistula, due to the relatively stable blood flow in this region. This may negate the need for a long cannulation segment and aid clinicians in optimizing needle placement for hemodialysis.
publisherThe American Society of Mechanical Engineers (ASME)
titleHigh-Resolution Computational Fluid Dynamic Simulation of Haemodialysis Cannulation in a Patient-Specific Arteriovenous Fistula
typeJournal Paper
journal volume140
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4038289
journal fristpage31011
journal lastpage031011-8
treeJournal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record