Show simple item record

contributor authorDaraji, Ali H.
contributor authorHale, Jack M.
contributor authorYe, Jianqiao
date accessioned2019-02-28T11:10:12Z
date available2019-02-28T11:10:12Z
date copyright9/29/2017 12:00:00 AM
date issued2018
identifier issn1048-9002
identifier othervib_140_01_011015.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253414
description abstractThis paper describes a computationally efficient method to determine optimal locations of sensor/actuator (s/a) pairs for active vibration reduction of a flexible structure. Previous studies have tackled this problem using heuristic optimization techniques achieved with numerous combinations of s/a locations and converging on a suboptimal or optimal solution after multithousands of generations. This is computationally expensive and directly proportional to the number of sensors, actuators, possible locations on structures, and the number of modes required to be suppressed (control variables). The current work takes a simplified approach of modeling a structure with sensors at all locations, subjecting it to external excitation force or structure base excitation in various modes of interest and noting the locations of n sensors giving the largest average percentage sensor effectiveness. The percentage sensor effectiveness is measured by dividing all sensor output voltage over the maximum for each mode using time and frequency domain analysis. The methodology was implemented for dynamically symmetric and asymmetric structures under external force and structure base excitations to find the optimal distribution based on time and frequency responses analysis. It was found that the optimized sensor locations agreed well with the published results for a cantilever plate, while with very much reduced computational effort and higher effectiveness. Furthermore, it was found that collocated s/a pairs placed in these locations offered very effective active vibration reduction for the structure considered.
publisherThe American Society of Mechanical Engineers (ASME)
titleNew Methodology for Optimal Placement of Piezoelectric Sensor/Actuator Pairs for Active Vibration Control of Flexible Structures
typeJournal Paper
journal volume140
journal issue1
journal titleJournal of Vibration and Acoustics
identifier doi10.1115/1.4037510
journal fristpage11015
journal lastpage011015-13
treeJournal of Vibration and Acoustics:;2018:;volume( 140 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record