Show simple item record

contributor authorGonfiotti, Bruno
contributor authorPaci, Sandro
date accessioned2019-02-28T11:05:25Z
date available2019-02-28T11:05:25Z
date copyright3/5/2018 12:00:00 AM
date issued2018
identifier issn2332-8983
identifier otherners_004_02_020902.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252564
description abstractThe estimation of fission products (FPs) release from the containment system of a nuclear plant to the external environment during a severe accident (SA) is a quite complex task. In the last 30–40 yr, several efforts were made to understand and to investigate the different phenomena occurring in such a kind of accidents in the primary coolant system and in the containment. These researches moved along two tracks: understanding of involved phenomenologies through the execution of different experiments and creation of numerical codes capable to simulate such phenomena. These codes are continuously developed to reflect the actual SA state of the art, but it is necessary to continuously check that modifications and improvements are able to increase the quality of the obtained results. For this purpose, also a continuous verification and validation work should be carried out. Therefore, the aim of the present work is to re-analyze the Phébus fission products test 1 (FPT-1) test employing the accident source term evaluation code (ASTEC) and MELCOR codes (respectively, ASTEC v.2.0 revision 3 patch 3 and MELCOR V2.1.6840 version). The analysis focuses on the stand-alone containment aspects of the test, and three different modelizations of the containment vessel have been developed showing that at least 15/20 control volumes (CVs) are necessary for the spatial schematization to correctly predict the test thermal hydraulics and the aerosol behavior. Furthermore, the paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and FPs behavior.
publisherThe American Society of Mechanical Engineers (ASME)
titleStand-Alone Containment Analysis of the Phébus Fission Products Test 1 With the ASTEC and the MELCOR Codes
typeJournal Paper
journal volume4
journal issue2
journal titleJournal of Nuclear Engineering and Radiation Science
identifier doi10.1115/1.4038059
journal fristpage20902
journal lastpage020902-15
treeJournal of Nuclear Engineering and Radiation Science:;2018:;volume( 004 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record