Show simple item record

contributor authorBaumgärtner, Max H.
contributor authorSattelmayer, Thomas
date accessioned2019-02-28T10:56:48Z
date available2019-02-28T10:56:48Z
date copyright10/31/2017 12:00:00 AM
date issued2018
identifier issn0742-4795
identifier othergtp_140_04_041505.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251057
description abstractThe increasing amount of volatile renewable energy sources drives the necessity of flexible conventional power plants to compensate for fluctuations of the power supply. Gas turbines in a combined cycle power plant (CCPP) adjust the power output quickly but a sudden increase of CO and unburned hydrocarbons emissions limits their turn-down ratio. To extend the turn-down ratio, part of the fuel can be processed to syngas, which exerts a higher reactivity. An autothermal on-board syngas generator in combination with two different burner concepts for natural gas (NG) and syngas mixtures is presented in this study. A mixture of NG, water vapor, and air reacts catalytically in an autothermal reactor test rig to form syngas. At atmospheric pressure, the fuel processor generates syngas with a hydrogen content of −30 vol % and a temperature of 800 K within a residence time of 200 ms. One concept for the combustion of NG and syngas mixtures comprises a generic swirl stage with a central lance injector for the syngas. The second concept includes a central swirl stage with an outer ring of jets. The combustion is analyzed for both concepts by OH*-chemiluminescence, lean blow out (LBO) limit, and gaseous emissions. The central lance concept with syngas injection exhibits an LBO adiabatic flame temperature that is 150 K lower than in premixed NG operation. For the second concept, an extension of almost 200 K with low CO emission levels can be reached. This study shows that autothermal on-board syngas generation is feasible and efficient in terms of turn-down ratio extension and CO burn-out.
publisherThe American Society of Mechanical Engineers (ASME)
titleLow Load Operation Range Extension by Autothermal On-Board Syngas Generation
typeJournal Paper
journal volume140
journal issue4
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4038016
journal fristpage41505
journal lastpage041505-9
treeJournal of Engineering for Gas Turbines and Power:;2018:;volume( 140 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record