Show simple item record

contributor authorAguilar, Jonathan
contributor authorBromberg, Leslie
contributor authorSappok, Alexander
contributor authorRagaller, Paul
contributor authorAtehortua, Jean
contributor authorLiu, Xiaojin
date accessioned2019-02-28T10:56:42Z
date available2019-02-28T10:56:42Z
date copyright7/9/2018 12:00:00 AM
date issued2018
identifier issn0742-4795
identifier othergtp_140_11_112805.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251040
description abstractMotivated by increasingly strict nitrogen oxides (NOx) limits, engine manufacturers have adopted selective catalytic reduction (SCR) technology to reduce engine-out NOx. In the SCR process, NOx react with ammonia (NH3) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NOx and/or NH3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF)-based method to directly monitor the ammonia storage state of the SCR. This approach utilizes the catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH3) were evaluated over a wide range of frequencies, temperatures, and exhaust conditions. The RF response to NH3 storage, desorption, and oxidation on the SCR was well correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10% of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NOx conversion and decrease urea consumption.
publisherThe American Society of Mechanical Engineers (ASME)
titleCatalyst Ammonia Storage Measurements Using Radio Frequency Sensing1
typeJournal Paper
journal volume140
journal issue11
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4040198
journal fristpage112805
journal lastpage112805-7
treeJournal of Engineering for Gas Turbines and Power:;2018:;volume( 140 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record