Show simple item record

contributor authorSingh Piyius Raj;Rai Durgesh C.
date accessioned2019-02-26T07:57:14Z
date available2019-02-26T07:57:14Z
date issued2018
identifier other%28ASCE%29EM.1943-7889.0001418.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250501
description abstractThe heat evolved during the hydration process may not dissipate properly due to the large size and poor thermal conductivity of mass concrete. Embedded cooling pipes of circulating water are generally used for heat removal from the interior of the concrete mass. This study experimentally shows that forced cooling helps reduce the interior temperature significantly; however, it leads to a reverse thermal gradient around the cooling pipe. This paper conducts a three-dimensional finite-element simulation of the hydration heat in concrete with a forced cooling system, modeling the circulating water with three-dimensional elements with diffusion and dispersion properties which accurately predict the experimentally observed temperature profile. Finite-element analysis also indicates the presence of high thermal stresses in concrete near the cooling pipe, mainly due to the extreme temperature gradient and temperature fluctuations. The results suggest a careful monitoring of heat removal using forced cooling to avoid a large thermal gradient and the likelihood of cracking.
publisherAmerican Society of Civil Engineers
titleEffect of Piped Water Cooling on Thermal Stress in Mass Concrete at Early Ages
typeJournal Paper
journal volume144
journal issue3
journal titleJournal of Engineering Mechanics
identifier doi10.1061/(ASCE)EM.1943-7889.0001418
page4017183
treeJournal of Engineering Mechanics:;2018:;Volume ( 144 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record