| contributor author | Mostafa Ahmed M.;El-Salakawy Ehab F. | |
| date accessioned | 2019-02-26T07:55:59Z | |
| date available | 2019-02-26T07:55:59Z | |
| date issued | 2018 | |
| identifier other | %28ASCE%29CC.1943-5614.0000831.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4250363 | |
| description abstract | This paper presents the experimental results of seven full-scale glass fiber-reinforced polymer (GFRP) reinforced concrete (RC) slab–column edge connections. The dimensions of the slabs were 2,8×1,55×2 mm with a square column measuring 3×3×2,2 mm. The test connections were divided into two series. Series 1 included three high-strength concrete (HSC) connections, investigating the effect of the flexural reinforcement ratio (.9, 1.35, and 1.8%); and Series 2 included four normal-strength concrete (NSC) connections, investigating the effect of the GFRP shear-reinforcement type (headed studs or corrugated bars) and pattern (six or eight lines of shear reinforcement). The test results showed that increasing the reinforcement ratio increased the punching capacity and the postcracking stiffness of the HSC connections. The test results also showed that the use of headed studs and corrugated bars increased the punching capacity and the deformability of the NSC connections. The test results were compared to the predictions of the Canadian and American design provisions for FRP-RC structures. | |
| publisher | American Society of Civil Engineers | |
| type | Journal Paper | |
| journal volume | 22 | |
| journal issue | 2 | |
| journal title | Journal of Composites for Construction | |
| identifier doi | 10.1061/(ASCE)CC.1943-5614.0000831 | |
| page | 4018001 | |
| tree | Journal of Composites for Construction:;2018:;Volume ( 022 ):;issue: 002 | |
| contenttype | Fulltext | |