Show simple item record

contributor authorHoang Vu;Kiyomiya Osamu;An Tongxiang
date accessioned2019-02-26T07:53:32Z
date available2019-02-26T07:53:32Z
date issued2018
identifier other%28ASCE%29BE.1943-5592.0001227.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250101
description abstractThe vibration behavior of a stay cable subjected to abrupt rupture due to lateral force was studied using model experiments. Based on the experimental results, the performance of an existing cable-stayed bridge was studied using numerical analysis in cases where stay cables are abruptly ruptured by lateral force. The experimental results show that the impact force currently recommended is insufficient. The impact force is more affected by the tensile stress of the cable during rupture than by the initial stress. The results of numerical analysis show that the cable-stayed bridge analyzed in this study lacks serviceability performance against losing multiple cables in a collision incident.
publisherAmerican Society of Civil Engineers
titleExperimental and Numerical Study of Lateral Cable Rupture in Cable-Stayed Bridges: Case Study
typeJournal Paper
journal volume23
journal issue6
journal titleJournal of Bridge Engineering
identifier doi10.1061/(ASCE)BE.1943-5592.0001227
page5018004
treeJournal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record