Show simple item record

contributor authorLiu Zhongxiang;Guo Tong;Hebdon Matthew H.;Zhang Zhaolei
date accessioned2019-02-26T07:39:17Z
date available2019-02-26T07:39:17Z
date issued2018
identifier other%28ASCE%29CF.1943-5509.0001203.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248524
description abstractSuspenders are critical force transmission components in suspension and arch bridges, which connect the girder to the main cable/arch. Field inspection indicates that short suspenders at the midspan or the ends of a bridge may be more prone to fatigue damage under cyclic traffic loads when coupled with the effects of corrosion. The damage has been frequently observed to occur at the lower ends of suspenders. To evaluate the safety of suspenders, a stochastic time-variant reliability assessment method is proposed, where the time-variant model for deterioration of steel wires and probabilistic critical limit states based on crack depth and failure area are integrated, so as to consider the combined effect of corrosion and cyclic loading. A case study on the suspenders of the Jiangyin Yangtze River Bridge was performed in which a finite-element analysis was conducted in conjunction with a comprehensive traffic model. The time-variant reliability indices of the short suspenders were obtained according to the proposed method, which resulted in recommendations for suspender maintenance and replacement.
publisherAmerican Society of Civil Engineers
titleCorrosion Fatigue Analysis and Reliability Assessment of Short Suspenders in Suspension and Arch Bridges
typeJournal Paper
journal volume32
journal issue5
journal titleJournal of Performance of Constructed Facilities
identifier doi10.1061/(ASCE)CF.1943-5509.0001203
page4018060
treeJournal of Performance of Constructed Facilities:;2018:;Volume ( 032 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record