Show simple item record

contributor authorPohoryles Daniel A.;Melo Jose;Rossetto Tiziana;D’Ayala Dina;Varum Humberto
date accessioned2019-02-26T07:38:44Z
date available2019-02-26T07:38:44Z
date issued2018
identifier other%28ASCE%29CC.1943-5614.0000865.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248469
description abstractExisting RC moment-resisting frames (MRF) built with inadequate detailing or before the introduction of detailed seismic design codes (pre-197s) are highly vulnerable to brittle failure mechanisms under earthquake loading. To prevent potentially catastrophic failures and consequent human and economic losses in future earthquakes, efficient and practical retrofit solutions are required for these buildings. This paper presents an experimental study focused on the development of retrofit solutions that adopt carbon fiber–reinforced polymers (CFRP) to improve the seismic performance of existing RC MRF at their beam–column connections. It is highlighted that to date, most experimental studies in this field used simplified test specimens that have ignored the presence of slabs and secondary beams at beam–column connections. This may lead to an unrealistic assessment of FRP retrofit schemes. Hence, in this study, results from six full-scale cyclic tests on typical pre-197s interior beam–column joints with slab and transverse beams are presented. The tests are used to assess three proposed CFRP schemes composed of a combination of FRP strengthening methods and selective slab weakening. Each scheme is designed to meet a distinct retrofit objective: (1) enhancement of the lateral-load capacity, (2) enhancement of ductility, and (3) enhancement of the lateral-load capacity and ductility, as well as changing the dominant failure mode of the joint from a column hinging mechanism to one where the plasticity is mainly concentrated in the beams. A comparison of the retrofitted specimens with the behavior of a deficient specimen and a specimen designed to modern guidelines highlights the successful achievement of the respective retrofit objectives and the necessity to weaken the slab to achieve a favorable failure mechanism that will allow compliance to be achieved with current retrofit codes.
publisherAmerican Society of Civil Engineers
titleExperimental Comparison of Novel CFRP Retrofit Schemes for Realistic Full-Scale RC Beam–Column Joints
typeJournal Paper
journal volume22
journal issue5
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0000865
page4018027
treeJournal of Composites for Construction:;2018:;Volume ( 022 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record