Show simple item record

contributor authorAngst Ueli M.;Büchler M.
date accessioned2019-02-26T07:34:39Z
date available2019-02-26T07:34:39Z
date issued2018
identifier other%28ASCE%29PS.1949-1204.0000306.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248020
description abstractBy means of numerical modeling and experimental measurements, this work addresses the longstanding controversy of whether or not IR (ohmic) drops need to be considered in on-potential cathodic protection criteria. The results suggest that the IR drop is of little importance in many situations of practical relevance, and that its adverse influence on assessing the effectiveness of corrosion protection is generally overrated. This suggests that on-potentials are in principle suitable to be directly used for determining if a cathodic protection (CP) system offers adequate corrosion protection. This is considered a relevant finding because on-potentials are straightforward to measure, and their interpretation is free of many of the difficulties associated with instant-off potentials. Irrespective of the parameter used, however, a number of issues are discussed that need to be addressed in further work in order to provide the knowledge required to settle on threshold values.
publisherAmerican Society of Civil Engineers
typeJournal Paper
journal volume9
journal issue1
journal titleJournal of Pipeline Systems Engineering and Practice
identifier doi10.1061/(ASCE)PS.1949-1204.0000306
page4017035
treeJournal of Pipeline Systems Engineering and Practice:;2018:;Volume ( 009 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record