Show simple item record

contributor authorGranello Gabriele;Leyder Claude;Palermo Alessandro;Frangi Andrea;Pampanin Stefano
date accessioned2019-02-26T07:34:16Z
date available2019-02-26T07:34:16Z
date issued2018
identifier other%28ASCE%29ST.1943-541X.0002101.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4247972
description abstractSince 21, twelve post-tensioned timber (Pres-Lam) buildings have been constructed throughout the world. The technology relies on unbonded post-tensioning tendons to provide moment capacity to beam-column, wall-foundation, or column-foundation connections. Supplemental energy dissipation can be introduced by mild steel bars or replaceable damping devices when designing buildings for high seismic risk areas. Creep within the timber elements leads to losses in post-tensioning force over time. The amount of post-tensioning loss depends on the members’ geometry, environmental service conditions, and the initial moisture content of wood. This paper presents a design approach for estimating, via hand calculations, the amount of post-tensioning loss expected for the most common design configurations.
publisherAmerican Society of Civil Engineers
titleDesign Approach to Predict Post-Tensioning Losses in Post-Tensioned Timber Frames
typeJournal Paper
journal volume144
journal issue8
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)ST.1943-541X.0002101
page4018115
treeJournal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record