Show simple item record

contributor authorKatz Amnon
date accessioned2019-02-26T07:33:42Z
date available2019-02-26T07:33:42Z
date issued2018
identifier other%28ASCE%29SC.1943-5576.0000379.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4247906
description abstractSignificant attention is given to the transport properties of the concrete covering the reinforcing bars (covercrete) while neglecting the statistical characteristic of its thickness resulting from variations in rebar placement. A statistics-based model was developed to evaluate the effect of variations in covercrete thickness on the equivalent service life of a structure. It was demonstrated that service life can diminish by ∼3% when the standard deviation of the covercrete thickness reaches 15 mm (.6 in.), as sometimes observed in practice. Field investigation of covercrete thickness in five infrastructure projects identified two sources of errors: (1) error in the average covercrete thickness, which indicates poor control of the specified thickness, and (2) standard deviation of thickness that ranges from 7.3 to 16.4 mm (.29 to .65 in.). As a result, the projects' equivalent service life ranged from .4 to .99, where higher values were obtained in projects in which the mean concrete cover thickness was much greater than specified.
publisherAmerican Society of Civil Engineers
titleStatistical Variations of Rebar Placement and Its Effect on Service Life
typeJournal Paper
journal volume23
journal issue3
journal titlePractice Periodical on Structural Design and Construction
identifier doi10.1061/(ASCE)SC.1943-5576.0000379
page4018017
treePractice Periodical on Structural Design and Construction:;2018:;Volume ( 023 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record