Show simple item record

contributor authorMinor Joseph E.;Norville H. Scott
date accessioned2019-02-26T07:31:45Z
date available2019-02-26T07:31:45Z
date issued2018
identifier other%28ASCE%29AE.1943-5568.0000292.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4247621
description abstractA single table permits the designer of architectural glazing systems to select glazing constructions that will meet specified design wind loads. This simplification of the glazing construction selection process employs, as working elements, the minimum load resistance of commonly used glass thicknesses and opening areas. The process is based on two principal observations: (1) heat-treated lites (heat strengthened and fully tempered) with relatively large areas of approximately 4.6–6.5 m2 (5–7 ft2) can carry relatively large design pressures in excess of 4.8 kPa (1 psf) acting alone, thus eliminating the need for load-sharing analysis in most common sizes of insulating glass units; and (2) the load resistances of commonly used monolithic and polyvinylbutyral-laminated lites with identical dimensions and designated thickness are close enough to be considered equal, within 14 Pa (3 psf).
publisherAmerican Society of Civil Engineers
titleSelection of Architectural Glazing Constructions without Calculations
typeJournal Paper
journal volume24
journal issue1
journal titleJournal of Architectural Engineering
identifier doi10.1061/(ASCE)AE.1943-5568.0000292
page4017036
treeJournal of Architectural Engineering:;2018:;Volume ( 024 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record