Show simple item record

contributor authorJulien Michels
contributor authorMichał Staśkiewicz
contributor authorChristoph Czaderski
contributor authorRenata Kotynia
contributor authorYunus Emre Harmanci
contributor authorMasoud Motavalli
date accessioned2017-12-30T13:03:34Z
date available2017-12-30T13:03:34Z
date issued2016
identifier other%28ASCE%29BE.1943-5592.0000835.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4245158
description abstractThis paper presents an investigation on the practicability and structural efficiency of prestressed carbon-fiber–reinforced polymer (CFRP) strips with a gradient anchorage in the framework of a bridge-strengthening application in Poland. The nonmechanical anchorage system avoids the installation of metallic bolts and plates, with the exception of a temporary support frame. Two 18.4-m-long large-scale prestressed concrete girders were produced following the drawings of the existing bridge construction. One girder served as a reference, and the second one was strengthened with two prestressed CFRP strips. In this case, the initial negative cambering was leveled out by a layer of dry shotcrete. CFRP strips with a prestrain of 0.58% were applied for flexural upgrading. Both girders with a total length of 18.4 m were finally statically loaded up to failure to assess the strengthening efficiency in flexure of the retrofitting technique used. Tensile failure of the CFRP strips was reached, indicating an optimal use of the composite reinforcement. The strengthened girder exhibited a ductile behavior up to strip rupture with a distinct steel yielding and a subsequent pronounced increase of the load-carrying capacity. For service load considerations, an enhancement of the cracking load of approximately 16% was noticed. In terms of ultimate load, a significant improvement of approximately 25% compared to the reference girder was reached. Although some practical problems need optimization, the presented results are very promising and make this strengthening system an alternative for future retrofitting applications in bridge engineering.
publisherAmerican Society of Civil Engineers
titlePrestressed CFRP Strips for Concrete Bridge Girder Retrofitting: Application and Static Loading Test
typeJournal Paper
journal volume21
journal issue5
journal titleJournal of Bridge Engineering
identifier doi10.1061/(ASCE)BE.1943-5592.0000835
page04016003
treeJournal of Bridge Engineering:;2016:;Volume ( 021 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record