Show simple item record

contributor authorGreen
contributor authorJoshua T.;Hale
contributor authorRena F.;Hausselle
contributor authorJerome;Gonzalez
contributor authorRoger V.
date accessioned2017-12-30T11:43:56Z
date available2017-12-30T11:43:56Z
date copyright9/28/2017 12:00:00 AM
date issued2017
identifier issn0148-0731
identifier otherbio_139_12_121001.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4242940
description abstractAdvancements in computational musculoskeletal biomechanics are constrained by a lack of experimental measurement under real-time physiological loading conditions. This paper presents the design, configuration, capabilities, accuracy, and repeatability of The University of Texas at El Paso Joint Load Simulator (UTJLS) by testing four cadaver knee specimens with 47 real-time tests including heel and toe squat maneuvers with and without musculotendon forces. The UTJLS is a musculoskeletal simulator consisting of two robotic manipulators and eight musculotendon actuators. Sensors include eight tension load cells, two force/torque systems, nine absolute encoders, and eight incremental encoders. A custom control system determines command output for position, force, and hybrid control and collects data at 2000 Hz. Controller configuration performed forward-dynamic control for all knee degrees-of-freedom (DOFs) except knee flexion. Actuator placement and specimen potting techniques uniquely replicate muscle paths. Accuracy and repeatability standard deviations across specimen during squat simulations were equal or less than 8 N and 5 N for musculotendon actuators, 30 N and 13 N for ground reaction forces (GRFs), and 4.4 N·m and 1.9 N·m for ground reaction moments. The UTJLS is the first of its design type. Controller flexibility and physical design support axis constraints to match traditional testing rigs, absolute motion, and synchronous real-time simulation of multiplanar kinematics, GRFs, and musculotendon forces. System DOFs, range of motion, and speed support future testing of faster maneuvers, various joints, and kinetic chains of two connected joints.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Reconfigurable Multiplanar In Vitro Simulator for Real-Time Absolute Motion With External and Musculotendon Forces
typeJournal Paper
journal volume139
journal issue12
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4037853
journal fristpage121001
journal lastpage121001-11
treeJournal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 012
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record