Show simple item record

contributor authorHunter Fanney
contributor authorA.;Healy
contributor authorWilliam;Payne
contributor authorVance;Kneifel
contributor authorJoshua;Ng
contributor authorLisa;Doughety
contributor authorBrian;Ullah
contributor authorTania;Omar
contributor authorFarhad
date accessioned2017-12-30T11:43:40Z
date available2017-12-30T11:43:40Z
date copyright9/28/2017 12:00:00 AM
date issued2017
identifier issn0199-6231
identifier othersol_139_06_061009.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4242869
description abstractThe Net-Zero Energy Residential Test Facility (NZERTF) was designed to be approximately 60% more energy efficient than homes meeting the 2012 International Energy Conservation Code requirements. The thermal envelope minimizes heat loss/gain through the use of advanced framing and enhanced insulation. A continuous air/moisture barrier resulted in an air exchange rate of 0.6 air changes per hour at 50 Pa. The home incorporates a vast array of extensively monitored renewable and energy efficient technologies including an air-to-air heat pump system with a dedicated dehumidification cycle; a ducted heat-recovery ventilation (HRV) system; a whole house dehumidifier; a photovoltaic system; and a solar domestic hot water system. During its first year of operation, the NZERTF produced an energy surplus of 1023 kWh. Based on observations during the first year, changes were made to determine if further improvements in energy performance could be obtained. The changes consisted of installing a thermostat that incorporated control logic to minimize the use of auxiliary heat, using a whole house dehumidifier in lieu of the heat pump's dedicated dehumidification cycle, and reducing the ventilation rate to a value that met but did not exceed code requirements. During the second year of operation, the NZERTF produced an energy surplus of 2241 kWh. This paper describes the facility, compares the performance data for the 2 years, and quantifies the energy impact of the weather conditions and operational changes.
publisherThe American Society of Mechanical Engineers (ASME)
titleSmall Changes Yield Large Results at NIST's Net-Zero Energy Residential Test Facility
typeJournal Paper
journal volume139
journal issue6
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.4037815
journal fristpage61009
journal lastpage061009-14
treeJournal of Solar Energy Engineering:;2017:;volume( 139 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record