description abstractAxial pipeline defects are detectable from torsional guided wave reflections through 90 deg elbows. This paper demonstrates that detection of localized damage in carbon steel pipes with a so-called standard long and very long radius elbow is possible using a single permanently installed source–receiver pair. We use dispersion imaging to determine why this is not possible in a short radius elbow pipe. Although the remote damage is detected in a standard short radius bend pipe, there is not enough signal to detect localized damage. Since pipeline bends are normally of at least standard long radius, the acoustical behavior is similar to that previously determined in straight pipes. The reflective method can thus be applied fruitfully to monitor structural health beyond industrial pipeline bends.
publisherThe American Society of Mechanical Engineers (ASME)
titleDamage Detection Through Pipe Bends
typeJournal Paper
journal volume139
journal issue5
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.4037120
journal fristpage51701
journal lastpage051701-7
treeJournal of Pressure Vessel Technology:;2017:;volume( 139 ):;issue: 005