Show simple item record

contributor authorKatz, Aric
contributor authorShtub, Avraham
contributor authorRoguin, Ariel
date accessioned2017-11-25T07:18:41Z
date available2017-11-25T07:18:41Z
date copyright2017/25/5
date issued2017
identifier issn2332-8983
identifier otherners_003_03_030905.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235324
description abstractAdvanced imaging systems, such as C-Arm machines, greatly improve physicians' diagnostic abilities and provide greater precision. Yet, these benefits come with a price of ionizing radiation exposure to medical teams and patients. Supplying proper training and skill improvement to operators on how to use this technology safely can help minimize risk of exposure. Previous studies on radiation knowledge among physicians and radiologists presented disturbing results of underestimated risk of exposure. The following research is based on an innovation in simulation-based training (SBT), a simulator using the Wizard of Oz (WOZ) concept that incorporates an online human trainer and was used for training emergency room (ER) physicians and ultrasound medical personnel. This research integrated WOZ technology with a radiation exposure formula for training to minimize unnecessary radiation exposure. The exposure formula presents real-time and overall exposure levels to operators based on their technique. The simulator also incorporates 3D animation graphics, enabling trainees to simulate the control of various factors. Image quality and the operator's radiation exposure levels are also animated, assisting trainees to focus on their exposure based on their device settings. Contrary to most previous studies, we measured radiation dose to the operator and quantified image quality accordingly. Validation was done on different C-Arm machines. Validation of learning outcomes was done using knowledge exams. Results from our knowledge exams presented significant improvement. The average result of knowledge exams given prior to training was 54%, whereas the average result after training was 94% (p < 0.001). Additionally, after a gap of 2–3 months, high retention was also found.
publisherThe American Society of Mechanical Engineers (ASME)
titleMinimizing Ionizing Radiation Exposure in Invasive Cardiology Safety Training for Medical Doctors
typeJournal Paper
journal volume3
journal issue3
journal titleJournal of Nuclear Engineering and Radiation Science
identifier doi10.1115/1.4036431
journal fristpage30905
journal lastpage030905-8
treeJournal of Nuclear Engineering and Radiation Science:;2017:;volume( 003 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record