| contributor author | Lancaster, Gilead I. | |
| contributor author | Hay, Ilan | |
| contributor author | Eldar, Michael | |
| date accessioned | 2017-11-25T07:18:32Z | |
| date available | 2017-11-25T07:18:32Z | |
| date copyright | 2017/27/6 | |
| date issued | 2017 | |
| identifier issn | 1932-6181 | |
| identifier other | med_011_03_031001.pdf | |
| identifier uri | http://138.201.223.254:8080/yetl1/handle/yetl/4235225 | |
| description abstract | This study sought to determine the feasibility of using noninvasive cardiac hemodynamics (NICHE), a new noninvasive Doppler-based device, to monitor real-time, simultaneous tissue and blood-flow Doppler measurements in a clinical setting, and to obtain preliminary performance data compared to a commercially available system. Doppler-based measurements have been shown to correlate well with invasive hemodynamic data and diastolic function, but their use in clinical applications has been limited by various technical issues. The NICHE device was developed to obtain simultaneous tissue and blood-flow Doppler measurements automatically, in real-time and in a hands-free manner. Thirty participants (ten normal volunteers and 20 patients in a cardiac rehab program) underwent standard echocardiographic/Doppler studies followed immediately by NICHE monitoring. Early diastolic transmitral blood-flow velocity (E) and tissue Doppler myocardial wall velocity during early relaxation (E′) were acquired using a standard echo device; and E/E′ was derived post hoc. NICHE measurements included E, E′, and directly measured instantaneous E/E′. NICHE was successfully used in 28 participants. Measurements of ENICHE ranged from 40 cm/s to over 120 cm/s and correlated well with Eecho (R = 0.93). ENICHE′ ranged from 2 to 23 cm/s and correlated well with the averaged Eecho′ (R = 0.91). Directly measured E/ENICHE′ ratios ranged from 3 to 23 and correlated well with derived E/Eecho′ (R = 0.91). The NICHE device can monitor patients in a hands-free manner and can supply real-time Doppler derived measurements of hemodynamic parameters and diastolic function that correlate well with measurements from standard echo devices. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Continuous, Real-Time, Noninvasive Hemodynamic Cardiac Doppler Monitoring With a Novel Hands-Free Device: A Feasibility Study Compared to Standard Echo | |
| type | Journal Paper | |
| journal volume | 11 | |
| journal issue | 3 | |
| journal title | Journal of Medical Devices | |
| identifier doi | 10.1115/1.4036024 | |
| journal fristpage | 31001 | |
| journal lastpage | 031001-6 | |
| tree | Journal of Medical Devices:;2017:;volume( 011 ):;issue: 003 | |
| contenttype | Fulltext | |