contributor authorSong, Chung R.
contributor authorYosef, Tewodros Y.
date accessioned2017-11-25T07:16:14Z
date available2017-11-25T07:16:14Z
date copyright2017/2/3
date issued2017
identifier issn0094-4289
identifier othermats_139_02_021024.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4233898
description abstractDistributed temperature sensing (DTS)-based fiber optic sensors are widely used for monitoring spatially continuous temperature distribution in structures. In this research, hydro-thermal (H-T) coupled analysis is used to monitor seepage conditions in an embankment dam. Variably saturated two-dimensional heat transport (VS2DHI), a computer code developed by the U.S. Geological Survey, was used for this coupled analysis. From the coupled analysis, the temperature profile for a dam with an artificially generated crack clearly showed the location of the crack. In addition, it turned out that the temperature change in the dam took much longer than the seepage time due to the additional time required for heat transfer. The study shows that temperature variation in the dam is comparable to the seepage condition with time delay for heat transfer. This study also shows the possibility that temperature data may serve as a tool to diagnose prior seepage conditions and past incidents of a dam.
publisherThe American Society of Mechanical Engineers (ASME)
titleSeepage Monitoring of an Embankment Dam Based on Hydro-Thermal Coupled Analysis
typeJournal Paper
journal volume139
journal issue2
journal titleJournal of Engineering Materials and Technology
identifier doi10.1115/1.4036020
journal fristpage21024
journal lastpage021024-9
treeJournal of Engineering Materials and Technology:;2017:;volume( 139 ):;issue: 002
contenttypeFulltext