Show simple item record

contributor authorBeaton, Stuart P.
contributor authorSpowart, Mike
date accessioned2017-06-09T17:24:14Z
date available2017-06-09T17:24:14Z
date copyright2012/09/01
date issued2012
identifier issn0739-0572
identifier otherams-84616.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4227972
description abstractnext-generation vacuum-ultraviolet (Lyman-alpha) absorption hygrometer for high-rate research aircraft humidity measurements designed by the National Center for Atmospheric Research is described. It retains the high data rate, optical and mechanical simplicity, and low maintenance of previous Lyman-alpha hygrometers, while incorporating modern electronics and rugged, long-lived commercially available lamps and detectors. The mass of the sensing head is 2.0 kg in a volume of 3700 cm3, while the power supply is 1.3 kg mass in a volume of 1100 cm3. Power draw is 0.2 A at 120 V alternating current (AC). In bench and aircraft flight testing the prototype shows a bandwidth of 35 Hz and mixing ratio noise of ±0.5% over a water vapor mixing ratio range of 2?15 g kg?1. This range can be scaled to lower mixing ratios by increasing the pathlength. This performance enables measurements of water vapor concentration with high spatial resolution from research aircraft. The prototype instrument has flown over 380 h with minimal maintenance or repairs.
publisherAmerican Meteorological Society
titleUV Absorption Hygrometer for Fast-Response Airborne Water Vapor Measurements
typeJournal Paper
journal volume29
journal issue9
journal titleJournal of Atmospheric and Oceanic Technology
identifier doi10.1175/JTECH-D-11-00141.1
journal fristpage1295
journal lastpage1303
treeJournal of Atmospheric and Oceanic Technology:;2012:;volume( 029 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record