Show simple item record

contributor authorChleck, David
date accessioned2017-06-09T16:47:34Z
date available2017-06-09T16:47:34Z
date copyright1966/12/01
date issued1966
identifier issn0021-8952
identifier otherams-7419.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4216389
description abstractFurther laboratory results with the aluminum oxide humidity sensor are described. It is concluded that the sensor has sufficient sensitivity, time response, accuracy and stability to be successfully employed in all portions of a balloon flight and parachute descent in the atmosphere. The results of a number of flights are shown. Frost point values between ?75C and ?96C at the tropopause were observed, indicating that stratospheric water content may be dependent on both location and time. The continuous pattern of increasing water content above the tropopause is consistent with the results of many investigations as compiled by Gutnick and Salmela.
publisherAmerican Meteorological Society
titleAluminum Oxide Hygrometer: Laboratory Performance and Flight Results
typeJournal Paper
journal volume5
journal issue6
journal titleJournal of Applied Meteorology
identifier doi10.1175/1520-0450(1966)005<0878:AOHLPA>2.0.CO;2
journal fristpage878
journal lastpage886
treeJournal of Applied Meteorology:;1966:;volume( 005 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record