Show simple item record

contributor authorPearlmutter, D.
contributor authorBerliner, P.
contributor authorShaviv, E.
date accessioned2017-06-09T16:47:29Z
date available2017-06-09T16:47:29Z
date copyright2005/04/01
date issued2005
identifier issn0894-8763
identifier otherams-74156.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4216350
description abstractThe thermal behavior of an urban surface is crucial to understand, but it is difficult to predict using conventional measurement or modeling approaches. In this study, an integrated method is proposed for evaluating urban energy exchanges with an open-air scale model of a building?street canyon surface array. The technique, which potentially combines the flexibility of modeling with the reliability of empirical observation under natural turbulence and radiative loading, is tested in hot, arid summer conditions to gauge its ability for reproducing surface?atmosphere energy fluxes that are representative of diurnal patterns in actual urban settings. After identifying the inertial sublayer, which is created above the scaled roughness array at a point near its downwind edge, roughness parameters utilized in the calculation of turbulent sensible heat flux are determined for two different array configurations of varying frontal area density and compared with existing data from field studies and morphometric models. For each geometric configuration, the relative sharing of radiant energy between storage and turbulent fluxes is compared with published findings obtained by conventional methods, as is the diurnal pattern of each component flux. Roughness parameters that are obtained conform to the expected ranges, as do daytime and overall daily fluxes and flux ratios. Overall, radiation absorption and heat storage are higher in the array with deeper canyons, and in both arrays the share of sensible heat channeled into the atmosphere is both higher in magnitude and later in reaching its peak intensity than that which is stored within the scaled urban fabric. This thermal time lag, when evaluated by fitting data to a published model for parameterizing heat storage from net radiation, shows a high correlation with hysteresis behavior in actual cities.
publisherAmerican Meteorological Society
titleEvaluation of Urban Surface Energy Fluxes Using an Open-Air Scale Model
typeJournal Paper
journal volume44
journal issue4
journal titleJournal of Applied Meteorology
identifier doi10.1175/JAM2220.1
journal fristpage532
journal lastpage545
treeJournal of Applied Meteorology:;2005:;volume( 044 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record