| contributor author | Sherif El-Tawil | |
| contributor author | Tameka Mikesell | |
| contributor author | Sashi K. Kunnath | |
| date accessioned | 2017-05-08T20:57:31Z | |
| date available | 2017-05-08T20:57:31Z | |
| date copyright | January 2000 | |
| date issued | 2000 | |
| identifier other | %28asce%290733-9445%282000%29126%3A1%2879%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/33280 | |
| description abstract | The effect of the local geometric details and yield-to-ultimate stress ratio on the inelastic behavior of pre-Northridge connections is studied through 3D nonlinear finite-element analyses of connection subassemblages. Geometric details considered include shape and size of the access hole and presence or absence of the continuity plate and its thickness. Results from the finite-element analyses highlight the detrimental effect of using steel with the high yield-to-ultimate stress ratio and show that enlarging the size of the access hole to facilitate welding increases the potential for ductile fracture at the root of the access hole. It is suggested that currently recommended provisions for continuity plate thickness could be relaxed for one-sided moment connections. | |
| publisher | American Society of Civil Engineers | |
| title | Effect of Local Details and Yield Ratio on Behavior of FR Steel Connections | |
| type | Journal Paper | |
| journal volume | 126 | |
| journal issue | 1 | |
| journal title | Journal of Structural Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9445(2000)126:1(79) | |
| tree | Journal of Structural Engineering:;2000:;Volume ( 126 ):;issue: 001 | |
| contenttype | Fulltext | |