Show simple item record

contributor authorSıddık Şener
contributor authorZdene˘k P. Baz˘ant
contributor authorEmilie Becq-Giraudon
date accessioned2017-05-08T20:57:25Z
date available2017-05-08T20:57:25Z
date copyrightJune 1999
date issued1999
identifier other%28asce%290733-9445%281999%29125%3A6%28653%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/33203
description abstractThe results of reduced-scale failure tests of simply supported four-point-bend beams of different sizes, containing lapped bond splices of smooth (undeformed) longitudinal reinforcing bars, are reported. The tests consist of two groups, with splices located either in the midspan region with a uniform bending moment, or in one of the end regions with a uniform shear force. The specimens were made of microconcrete with a maximum aggregate size 4.76 mm. Beams of three different heights (50, 100, and 200 mm) were tested. The beams were geometrically similar in three dimensions, and even the bar diameters and cover thicknesses were scaled in proportion. The reinforcement ratio was 0.31%. The results reveal the existence of a significant size effect, which can be approximately described by the size effect law previously proposed by Ba
publisherAmerican Society of Civil Engineers
titleSize Effect on Failure of Bond Splices of Steel Bars in Concrete Beams
typeJournal Paper
journal volume125
journal issue6
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1999)125:6(653)
treeJournal of Structural Engineering:;1999:;Volume ( 125 ):;issue: 006
contenttypeFulltext