description abstractAn innovative seismic upgrading technique for existing reinforced concrete frame connections constructed prior to the 1970s using corrugated steel jacketing is proposed and evaluated. Six, one-third scale, reinforced concrete beam-to-column connections were tested under quasi-static cyclic loading to study their seismic performance. The investigated test parameters include the amount of joint and column transverse reinforcement, corrugated steel sheet thicknesses, and jacketing of column only or of both column and beam. Test results demonstrated that existing reinforced concrete frame connections upgraded using corrugated steel jackets performed satisfactorily when subjected to high cyclic load levels. The corrugated steel jacket was found to be an effective system of upgrading as it increases the joint shear strength and the energy dissipation capacity. A method for the design of the corrugated steel jacket thickness and depth of corrugation is formulated.
publisherAmerican Society of Civil Engineers
titleUpgrading of Nonductile Reinforced Concrete Frame Connections
typeJournal Paper
journal volume123
journal issue8
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1997)123:8(1001)
treeJournal of Structural Engineering:;1997:;Volume ( 123 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record