Show simple item record

contributor authorDaniel N. Farhey
contributor authorMoshe A. Adin
contributor authorDavid Z. Yankelevsky
date accessioned2017-05-08T20:55:47Z
date available2017-05-08T20:55:47Z
date copyrightNovember 1995
date issued1995
identifier other%28asce%290733-9445%281995%29121%3A11%281710%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/32135
description abstractResults of laboratory tests on four repaired reinforced-concrete flat-slab interior column connections, carrying quasi-static, reversed, horizontal loadings are presented. The specimens, which originally had totally failed, were repaired and subjected to gradually increasing reversed loading histories, similar to those imposed on the original specimens. A comparative analysis was made before the repair. The specimens were repaired by using externally screwed steel plates replacing the lost or damaged full reinforcement of the slab. In addition, high-pressure epoxy injection provided the bond between the concrete and the new reinforcement. Moreover, this repair method can be easily used to restore, strengthen, or upgrade existing and old flat-slab buildings, not suitably designed to withstand earthquakes. The practical aspects of the repair technique developed for postearthquake mass production were emphasized, with satisfactory results even when not applied by research laboratory experts.
publisherAmerican Society of Civil Engineers
titleRepaired RC Flat-Slab-Column Subassemblages under Lateral Loading
typeJournal Paper
journal volume121
journal issue11
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1995)121:11(1710)
treeJournal of Structural Engineering:;1995:;Volume ( 121 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record