Show simple item record

contributor authorM. Ahmad
contributor authorE. Y. L. Chien
contributor authorM. U. Hosain
date accessioned2017-05-08T20:54:28Z
date available2017-05-08T20:54:28Z
date copyrightNovember 1992
date issued1992
identifier other%28asce%290733-9445%281992%29118%3A11%283222%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/31301
description abstractThis paper summarizes the results of load tests on two full‐size stub‐girders. The first, specimen M‐1, had a conventional girder‐to‐column connection and the second, specimen M‐2, featured a modified connection in which an extended end stub was connected to the column support. The modified end details offer some economic advantages, greater convenience for the erection and for installation of services. The test specimens were designed as spandrel stub girders for a typical office floor loading and consisted of three continuous spans. The concrete slab was continuous over the end supports of the interior span. The test results indicated that the stub girder with the modified end details is structurally as efficient as the conventional system. Specimen M‐1 failed by shear yielding of the steel girder, while specimen M‐2 failed by crushing of the concrete slab. The measured ultimate loads were 1.58 and 1.81 times the design factored load for specimens M‐1 and M‐2, respectively. Specimen M‐2, with the modified girder‐to‐column connection, exhibited a 14% increase in the observed ultimate strength over specimen M‐1.
publisherAmerican Society of Civil Engineers
titleModified Stub‐Girder Floor System: Full‐Scale Tests
typeJournal Paper
journal volume118
journal issue11
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1992)118:11(3222)
treeJournal of Structural Engineering:;1992:;Volume ( 118 ):;issue: 011
contenttypeFulltext