Show simple item record

contributor authorDimos Polyzois
date accessioned2017-05-08T20:52:36Z
date available2017-05-08T20:52:36Z
date copyrightJuly 1987
date issued1987
identifier other%28asce%290733-9445%281987%29113%3A7%281521%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/30118
description abstractAlthough cold‐formed sections provide substantial savings, because of their high strength‐to‐weight ratio, their cross‐sectional configuration gives rise to behavioral phenomena not encountered in the more familiar hotrolled sections. Of great concern to structural engineers is the tendency of these members to deform under most conditions of loading and to fail by yielding or local buckling as a result of the stresses developed. Channels and Z‐sections are commonly used as girts and purlins. In many installations, sag rods are used to provide alignment for these members for the attachment of the steel panels and to reduce their tendency to bend laterally and twist. Test results indicate that the presence of sag rods may not always be beneficial to the girts or purlins and, in fact, may cause premature distortional buckling of the compression flange.
publisherAmerican Society of Civil Engineers
titleSag Rods as Lateral Supports for Girts and Purlins
typeJournal Paper
journal volume113
journal issue7
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1987)113:7(1521)
treeJournal of Structural Engineering:;1987:;Volume ( 113 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record