| description abstract | The study of RBC scale‐up was conducted by using more than 60 data sets obtained from the operation of full‐scale and pilot‐scale treatment plants. The mathematical model developed earlier by Wu, et al. along with the nonlinear least squares regression method were used to analyze the data and also to determine the process scale‐up factor (SUF). The relationship between SUF and wastewater temperature under different operating conditions was successfully established. An example is given to demonstrate the usage of the SUF for full‐scale plant design. | |
| publisher | American Society of Civil Engineers | |
| title | Temperature Effects on RBC Scale‐Up | |
| type | Journal Paper | |
| journal volume | 109 | |
| journal issue | 2 | |
| journal title | Journal of Environmental Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9372(1983)109:2(321) | |
| tree | Journal of Environmental Engineering:;1983:;Volume ( 109 ):;issue: 002 | |