description abstractA procedure is described for automated sizing of the members and selection of pretension values for guyed antenna towers. The towers consist of a triangular cross section, tubular member mast supported by a number of sets of pretensioned guys. The sizing procedure employs a nonlinear finite element analysis coupled to a nonlinear mathematical programming based optimizer. Numerical studies were performed on a typical VLF antenna configuration to obtain minimum weight tower designs. Various loading conditions, tower heights, and tower materials were considered.
publisherAmerican Society of Civil Engineers
titleMinimum Weight Sizing of Guyed Antenna Towers
typeJournal Paper
journal volume111
journal issue10
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1985)111:10(2121)
treeJournal of Structural Engineering:;1985:;Volume ( 111 ):;issue: 010