Show simple item record

contributor authorAlex Coull
contributor authorYang Chee Wong
date accessioned2017-05-08T20:50:55Z
date available2017-05-08T20:50:55Z
date copyrightOctober 1984
date issued1984
identifier other%28asce%290733-9445%281984%29110%3A10%282531%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/29143
description abstractA finite element analysis is made of the interaction between floor slabs and laterally loaded shear walls that include a doorway opening for internal circulation within apartments. Particular attention is paid to the influence of local elastic wall deformation on the effective width and coupling stiffness of the slab. The influence of the size and position of the doorway opening is examined for a typical wall-slab configuration. It is concluded that the presence of a doorway opening does not significantly affect the effective slab stiffness.
publisherAmerican Society of Civil Engineers
titleInfluence of Door Openings on Effective Slab Width
typeJournal Paper
journal volume110
journal issue10
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1984)110:10(2531)
treeJournal of Structural Engineering:;1984:;Volume ( 110 ):;issue: 010
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record