contributor authorDardo O. Guaraglia
contributor authorJorge L. Pousa
date accessioned2017-05-08T20:49:45Z
date available2017-05-08T20:49:45Z
date copyrightJune 2006
date issued2006
identifier other%28asce%290733-9437%282006%29132%3A3%28284%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/28440
description abstractThe probe of a commercial thermal groundwater flowmeter was evaluated in the laboratory to determine the causes of apparent inaccurate results from field experiments conducted under high groundwater velocities in a gravel and coarse sand soil. The test was performed with water velocities from 2.3 to 103 m/day. Errors as large as 40% arose in the magnitude and direction of velocities within the measuring range specified by the manufacturer. The poor cosine response of the thermal sensor axes was found to be a major source of errors, because the accuracy of the velocity vector depends strongly on the angular response of the thermal sensor axes. This was partially corrected with a set of coefficients determined from laboratory tests.
publisherAmerican Society of Civil Engineers
titleDecreasing Measuring Errors of a Thermal Groundwater Flowmeter
typeJournal Paper
journal volume132
journal issue3
journal titleJournal of Irrigation and Drainage Engineering
identifier doi10.1061/(ASCE)0733-9437(2006)132:3(284)
treeJournal of Irrigation and Drainage Engineering:;2006:;Volume ( 132 ):;issue: 003