Show simple item record

contributor authorD. W. DeBoer
contributor authorK. A. Stange
contributor authorD. L. Beck
date accessioned2017-05-08T20:49:12Z
date available2017-05-08T20:49:12Z
date copyrightOctober 2001
date issued2001
identifier other%28asce%290733-9437%282001%29127%3A5%28272%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/28068
description abstractWater application characteristics of a very low pressure spray sprinkler (40 kPa), a low pressure spray sprinkler (100 kPa), a medium pressure impact sprinkler (170 kPa), and a high pressure impact sprinkler (345 kPa) were evaluated under field conditions. Average field application rates varied from 42 to 156 mm/h and maximum 5-min application rates varied from 54 to 226 mm/h. Both were inversely related to sprinkler nozzle pressure in a manner that can be described by a logarithmic relationship. Maximum 5-min and 10-min application rates were, respectively, about 20 and 10% higher than average rates for the irrigation events. The 100, 170, and 345 kPa sprinklers produced application uniformity coefficients of 95% for single events and up to 99% for sequential events. About 70% of applied irrigation water reached the soil surface within a 200-mm diameter area at the base of corn plants. Maximum water application rates at the base of corn plants were amplified from three to four times when compared with above-canopy rates.
publisherAmerican Society of Civil Engineers
titleSprinkler and Corn Canopy Effects on Water Application Characteristics
typeJournal Paper
journal volume127
journal issue5
journal titleJournal of Irrigation and Drainage Engineering
identifier doi10.1061/(ASCE)0733-9437(2001)127:5(272)
treeJournal of Irrigation and Drainage Engineering:;2001:;Volume ( 127 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record