| contributor author | Walter L. Trimmer | |
| contributor author | John A. Fazio | |
| date accessioned | 2017-05-08T20:47:22Z | |
| date available | 2017-05-08T20:47:22Z | |
| date copyright | January 1991 | |
| date issued | 1991 | |
| identifier other | %28asce%290733-9437%281991%29117%3A1%2891%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/27213 | |
| description abstract | Four two‐stage pipe expansions were designed, constructed, and tested to estimate their annual operating cost in irrigation service. The hydraulic performances of these fittings were compared with past two‐stage expansion research. The fittings were compared to other commonly used pipe expansions to determine their economic competitiveness. Measured head‐loss coefficients for the two‐stage pipe expansions averaged 0.32 and 0.28 for the 50–100 mm and 75–150 mm expansions, respectively. Loss coefficients for the 100–200 mm and 125–250 mm averaged 0.17 and 0.16, respectively. The smaller two fittings performed worse than past research on two‐stage expansions would predict. The two larger fittings (100–200 mm and 125–250 mm) worked substantially better than predicted. The two‐stage fittings presented in this paper are practical alternatives to other pipe expansions under the pumping conditions typically seen in irrigation service. The two‐stage pipe expansions designed with commonly available parts were more efficient than comparable abrupt and single‐stage pipe expansions, and cost about the same. | |
| publisher | American Society of Civil Engineers | |
| title | Practical Two‐Stage Pipe Expansions for Centrifugal Pumps | |
| type | Journal Paper | |
| journal volume | 117 | |
| journal issue | 1 | |
| journal title | Journal of Irrigation and Drainage Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9437(1991)117:1(91) | |
| tree | Journal of Irrigation and Drainage Engineering:;1991:;Volume ( 117 ):;issue: 001 | |
| contenttype | Fulltext | |