Show simple item record

contributor authorGeorge C. Christodoulou
date accessioned2017-05-08T20:47:21Z
date available2017-05-08T20:47:21Z
date copyrightJanuary 1991
date issued1991
identifier other%28asce%290733-9437%281991%29117%3A1%2837%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/27207
description abstractIn urban drainage networks on steep terrain, drop manholes are often employed for energy dissipation and reduction of flow velocities. The hydraulic behavior of such circular manholes located between supercritical pipe segments is studied by means of laboratory experiments. It is found that the local head‐loss coefficient is governed solely by a dimensionless drop parameter, expressed in terms of the drop height and the inflow velocity. An analytical expression based on the experimental results is proposed for practical applications. The water level inside the manhole depends also on the angle between the inflow and outflow pipes, being higher when they are normal as compared to parallel. Optimum ranges of the drop parameter, in order to avoid impediment to the flow by formation of a hydraulic jump or surcharging of the pipe, may be determined and used in engineering practice.
publisherAmerican Society of Civil Engineers
titleDrop Manholes in Supercritical Pipelines
typeJournal Paper
journal volume117
journal issue1
journal titleJournal of Irrigation and Drainage Engineering
identifier doi10.1061/(ASCE)0733-9437(1991)117:1(37)
treeJournal of Irrigation and Drainage Engineering:;1991:;Volume ( 117 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record