| contributor author | Tae Hoon Yoon | |
| date accessioned | 2017-05-08T20:45:00Z | |
| date available | 2017-05-08T20:45:00Z | |
| date copyright | November 2005 | |
| date issued | 2005 | |
| identifier other | %28asce%290733-9429%282005%29131%3A11%28942%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/25836 | |
| description abstract | As a new alternative countermeasure to riprap for scour protection around bridge piers, wire gabions were investigated experimentally for failure mechanisms, effects of significant parameters on failure and its sizing in a clear-water condition. The dominating failure mechanism was found to be a shear failure. Based on the experimental data, the controlling factors for the stability of wire gabions as a scour countermeasure at the pier are flow depth relative to pier diameter, length to thickness ratio, coverage, alignment and placement depth of wire gabions. An equation for sizing of a wire gabion is proposed in terms of Froude number and factors reflecting both the effect and limit of significant parameters. Comparison of the equation with those of ripraps shows that smaller wire gabions than ripraps provide an equivalent protection implying cost effective and improved stability. | |
| publisher | American Society of Civil Engineers | |
| title | Wire Gabion for Protecting Bridge Piers | |
| type | Journal Paper | |
| journal volume | 131 | |
| journal issue | 11 | |
| journal title | Journal of Hydraulic Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9429(2005)131:11(942) | |
| tree | Journal of Hydraulic Engineering:;2005:;Volume ( 131 ):;issue: 011 | |
| contenttype | Fulltext | |