description abstractTests of emergency heat removal pump sumps of nuclear power stations were conducted. A variety of approach flow patterns and different sump geometries tested gave rise to a wide range of circulation contributing to vortices of varying types and strengths. This paper presents the air-ingestion data for a wide range of Froude numbers and circulations. These data may be useful in obtaining indications of maximum likely air ingestions due to free-surface vortices at a pump intake.
publisherAmerican Society of Civil Engineers
titleAir Ingestion Due to Free‐surface Vortices
typeJournal Paper
journal volume110
journal issue12
journal titleJournal of Hydraulic Engineering
identifier doi10.1061/(ASCE)0733-9429(1984)110:12(1855)
treeJournal of Hydraulic Engineering:;1984:;Volume ( 110 ):;issue: 012