| contributor author | M. Padmanabhan | |
| date accessioned | 2017-05-08T20:38:49Z | |
| date available | 2017-05-08T20:38:49Z | |
| date copyright | December 1984 | |
| date issued | 1984 | |
| identifier other | %28asce%290733-9429%281984%29110%3A12%281855%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/22254 | |
| description abstract | Tests of emergency heat removal pump sumps of nuclear power stations were conducted. A variety of approach flow patterns and different sump geometries tested gave rise to a wide range of circulation contributing to vortices of varying types and strengths. This paper presents the air-ingestion data for a wide range of Froude numbers and circulations. These data may be useful in obtaining indications of maximum likely air ingestions due to free-surface vortices at a pump intake. | |
| publisher | American Society of Civil Engineers | |
| title | Air Ingestion Due to Free‐surface Vortices | |
| type | Journal Paper | |
| journal volume | 110 | |
| journal issue | 12 | |
| journal title | Journal of Hydraulic Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9429(1984)110:12(1855) | |
| tree | Journal of Hydraulic Engineering:;1984:;Volume ( 110 ):;issue: 012 | |
| contenttype | Fulltext | |