Show simple item record

contributor authorQuerol, Andrea
contributor authorGallardo, Sergio
contributor authorVerdأ؛, Gumersindo
date accessioned2017-05-09T01:32:08Z
date available2017-05-09T01:32:08Z
date issued2016
identifier issn2332-8983
identifier otherNERS_2_2_021020.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/162175
description abstractDuring lossofcoolant accidents (LOCAs), operators may start accident management (AM) actions when the core exit temperature (CET) measured by thermocouples exceeds a certain value. However, a significant time delay and temperature discrepancy in the superheat detection were observed in several facilities. This work is focused on clarifying CET thermocouple responses versus peak cladding temperature (PCT) and studying if the same physical phenomena are reproduced in two TRACE5 models with different geometry (a largescale test facility (LSTF) and a scaledup LSTF) during a pressure vessel (PV) upper head small break LOCA (SBLOCA). Results obtained show that the delay between the core uncover and the CET excursion is reproduced in both cases.
publisherThe American Society of Mechanical Engineers (ASME)
titleAnalysis of the Core Exit Temperature and the Peak Cladding Temperature During a SBLOCA: Application to a Scaled Up Model
typeJournal Paper
journal volume2
journal issue2
journal titleJournal of Nuclear Engineering and Radiation Science
identifier doi10.1115/1.4031016
journal fristpage21020
journal lastpage21020
treeJournal of Nuclear Engineering and Radiation Science:;2016:;volume( 002 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record