Show simple item record

contributor authorKim, Jangwoo
contributor authorRo, Paul I.
date accessioned2017-05-09T01:23:45Z
date available2017-05-09T01:23:45Z
date issued2015
identifier issn1948-5085
identifier othertsea_007_02_021001.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/159701
description abstractA feasibility study on developing a smallscale thermoacoustic cooler based on form and size factors for a typical cell phone is presented. First, an approximate analytical model for the temperature difference was derived using the linear theory of thermoacoustics. Cooling performance could be reasonably predicted with the analytical model proposed in this study. Air and helium as the working gases and the operating frequencies of 3 kHz for air and 9.2 kHz for helium are considered within the scope of typical cell phone configurations. A stack as a core of thermoacoustic cooler is designed to accomplish the most effective performance based on normalized parameters. For the 57 mm thermoacoustic cooler operating at 3 kHz with air, the maximum temperature difference of 23.13 آ°C across the stack in the resonance cavity is achieved with a drive ratio of 2% with air as the medium and Mylar as a stack material. This temperature difference varies depending on the stack placement along the length of the resonance cavity, but the maximum difference was achieved when the center of stack is placed at around 7 mm away from the driver end. The drive ratio, which is proportional to the power required to produce the thermoacoustic effect, is shown to be directly related to the cooling performance achieved by thermoacoustic drivers. For example, while a drive ratio of 2% results in a temperature difference of over 20 آ°C at its maximum, a drive ratio of 0.2% causes a temperature difference less than 1 آ°C. This will be one of hardware issues to be considered in making commercially viable products. The possibility of omitting heat exchangers in the thermoacoustic cooler is investigated considering their manufacturing cost and the relatively minute improvement they bring to overall cooling for smallscale systems. The numerical result of the thermoacoustic cooling system based on design environment for lowamplitude thermoacoustic energy conversion (DeltaEC) is compared to the theoretical result. Discrepancies between the two results exist in the range of 10–15% mainly due to the limitation imposed by short stack considerations and the linear theory of thermoacoustics.
publisherThe American Society of Mechanical Engineers (ASME)
titleFeasibility Study on Thermoacoustic Cooling for Low Power Handheld Electronic Devices
typeJournal Paper
journal volume7
journal issue2
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4029351
journal fristpage21001
journal lastpage21001
identifier eissn1948-5093
treeJournal of Thermal Science and Engineering Applications:;2015:;volume( 007 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record