| contributor author | Christian, Joshua | |
| contributor author | Moya, Adam | |
| contributor author | Ho, Clifford | |
| contributor author | Andraka, Charles | |
| contributor author | Yuan, James | |
| date accessioned | 2017-05-09T01:23:29Z | |
| date available | 2017-05-09T01:23:29Z | |
| date issued | 2015 | |
| identifier issn | 0199-6231 | |
| identifier other | sol_137_03_031014.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/159610 | |
| description abstract | Current heliostats cost ∼$200/m2 of reflective area and are estimated to contribute up to 50% of the total solar power tower plant costs. A drastic overall cost reduction is required in order for concentrated solar thermal power to be economically viable. The Department of Energy has set forth the SunShot initiative targeting a levelized cost of energy (LCOE) of $0.06/kWh by the year 2020. The cost of each heliostat must be brought down to an estimated $75/m2 to achieve this rigorous goal. One of the driving aspects of heliostat design and cost are the heliostat optical errors. At the moment, it is relatively unclear about the amount of error that can be present in the system while still maintaining low cost and high optical accuracy. The optical errors present on heliostat mirror surfaces directly influence the plant LCOE by causing beam spillage. This can result in an increase in the number of heliostats, an increased receiver size, and decreased thermal efficiency. Assuming a fixed heliostat cost of $75/m2, the effects of optical errors on LCOE were evaluated within the software delsol. From a probabilistic analysis, beam quality errors (i.e., slope error, alignment errors, etc.) were shown to have more importance on the LCOE than tracking errors. This determination resulted in a realization that the tracking errors and beam quality errors could be combined into a “bundled†rootsumsquare (RSS) error value and produce similar results in delsol. A “bundled†error value of 2 mrad resulted in an LCOE of $0.06/kWh. This “bundled†value was the basis for a new optical error budget and is decomposed into five individual errors. These five errors can be used as design specifications for new generation heliostats. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Probabilistic Analysis to Quantify Optical Performance and Error Budgets for Next Generation Heliostats | |
| type | Journal Paper | |
| journal volume | 137 | |
| journal issue | 3 | |
| journal title | Journal of Solar Energy Engineering | |
| identifier doi | 10.1115/1.4029376 | |
| journal fristpage | 31014 | |
| journal lastpage | 31014 | |
| identifier eissn | 1528-8986 | |
| tree | Journal of Solar Energy Engineering:;2015:;volume( 137 ):;issue: 003 | |
| contenttype | Fulltext | |