Show simple item record

contributor authorSchollenberger, Frederick S.
contributor authorKreith, Frank
contributor authorBurch, Jay
date accessioned2017-05-09T01:23:27Z
date available2017-05-09T01:23:27Z
date issued2015
identifier issn0199-6231
identifier othersol_137_03_031003.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/159598
description abstractPassive integral collector storage (ICS) solar water heaters can potentially heat water at lower costs then active systems with freeze protection. However, ICS panels can freeze in cold weather. This study developed a model relating the freeze behavior to climate conditions, validated the model experimentally and then ran the model with long term U.S. weather data to delineate regions safe for the passive solar heaters. Both, a singleand a doubleglazed tubular ICS panels were modeled and tested. It was found that freezing begins when the water in the supply/return lines freezes and initiates a pressure build up in the collector which can eventually burst the large collector tubes when the water inside freezes and expands. It was found that freezing can be delayed by installing heat tape over the supply/return lines. Using a model of the collector and TMY2 weather data, correlation maps were developed to show in which regions of the U.S. ICS panels with and without heat tapes can be installed safely.
publisherThe American Society of Mechanical Engineers (ASME)
titleGeographical Limitations on Integral Collector Storage Collectors Due to Freezing
typeJournal Paper
journal volume137
journal issue3
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.4028913
journal fristpage31003
journal lastpage31003
identifier eissn1528-8986
treeJournal of Solar Energy Engineering:;2015:;volume( 137 ):;issue: 003
contenttypeFulltext