Show simple item record

contributor authorPro،ek, Andrej
contributor authorVolkanovski, Andrija
date accessioned2017-05-09T01:22:30Z
date available2017-05-09T01:22:30Z
date issued2015
identifier issn2332-8983
identifier otherNERS_1_4_041016.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/159326
description abstractThe purpose of the study was to investigate the application of deterministic safety analysis for a prevention strategy of the extended station blackout (SBO). A method for the assessment of portable pump flow rates for a steam generator (SG) makeup is proposed. The RELAP5/MOD3.3 computer code and input model of a twoloop pressurized water reactor (PWR) is used for analyses, assuming different injection start times, flow rates, and reactor coolant system (RCS) losses. The calculated results show the effectiveness of the proposed extended SBO prevention strategy. The results demonstrate the need for mitigation of the common cause failure (CCF) potential of the onsite and offsite power sources.
publisherThe American Society of Mechanical Engineers (ASME)
titleRELAP5/MOD3.3 Analyses for Prevention Strategy of Extended Station Blackout
typeJournal Paper
journal volume1
journal issue4
journal titleJournal of Nuclear Engineering and Radiation Science
identifier doi10.1115/1.4030834
journal fristpage41016
journal lastpage41016
treeJournal of Nuclear Engineering and Radiation Science:;2015:;volume( 001 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record