Show simple item record

contributor authorRodney S. Thurston
date accessioned2017-05-09T01:20:56Z
date available2017-05-09T01:20:56Z
date copyrightJanuary, 1961
date issued1961
identifier issn1528-8919
identifier otherJETPEZ-26612#69_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/158833
description abstractThe effect of transient suction pressure decay on a centrifugal boiler feed pump has been under study by Karassik, et al. Using concepts established by these authors, this paper presents an analytical method for determining the minimum permissible weight of water ratio between the deaerator storage tank and the suction piping to the boiler feed pump. With sufficient capacity this tank is capable of insuring against flashing at the pump’s suction, thereby avoiding cavitation and vapor binding of the pump.
publisherThe American Society of Mechanical Engineers (ASME)
titleDesign of Suction Piping and Deaerator Storage Capacity to Protect Feed Pumps
typeJournal Paper
journal volume83
journal issue1
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.3673142
journal fristpage69
journal lastpage71
identifier eissn0742-4795
keywordsSuction
keywordsDesign
keywordsPipes
keywordsPumps
keywordsStorage
keywordsBoilers
keywordsWater
keywordsStorage tanks
keywordsCavitation
keywordsFlashing
keywordsWeight (Mass)
keywordsPressure AND Vapors
treeJournal of Engineering for Gas Turbines and Power:;1961:;volume( 083 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record